DGC-III+ NIBP/SPO2/TEMP PATIENT MONITOR ★. Four Parameters: NIBP,SPO2,TEMP,PR ★. One Waveform: SPO2 waveform (PLETH) Features: ★. Intelligent monitoring NIBP,SPO2,PR,Pulse Strength,PLETH and TEMP; ★. Bright and clear LED and LCD display ; ★. Compact,light for handing and easy operation; ★. Audio and visual alarm when sensors off or alarm limit exceeded; ★. Storage and review of patient's NIBP data up to 900 groups and SPO2,TEMP trend data up to 3150 groups.The data is never lost even when power's off; ★. Three kinds of power supply, AC Power, Build-in rechargeable Li-ion battery and Common AA alkaline or rechargeable batteries; ★. Automatic shut down,shut down time adjustable from 2~15Min ; ★. History data uploading to a personal computer for display,observing and printing; Applications: ● This model can be applied in the hospital’s operation room, ICU, clinic section office, Out-patient department, sickroom and emergency treatment. Standard Packing List: ■ NIBP extension tube 1pc ■ Adult NIBP cuff 1pc ■ Adult SPO2 Sensor(include TEMP Probe) 1pc ■ AC power adaptor 1pc ■ Communication cable 1pc Selectable Accessory: ● Pediatric NIBP cuff ● Pediatric SPO2 sensor ● H.S. Code: 90181930 ● Dimension: 160mm×148mm×85mm ● Net Weight: 565g ● Gross Weight: 980g ● Package Size: 245×185×100mm Technical Specifications: NIBP ● Patient: Adult and Pediatric ● Measurement method: Oscillometric ● Range: Adult:30mmHg~255mmHg Pediatric: 30mmHg~160mmHg ● Measurement unite: mmHg/kPa selectable ● Measurement mode: Manual, Auto, STAT ● Measurement Type: SYS, DIA, MAP ● Measurement interval in AUTO mode: 1,2,3,5,10,15,20,30,45,60Min ● Measuring period in STAT mode: 5 Min ● Resolution: 1mmHg ● Over-pressure protection: Adult:300mmHg Pediatric:220mmHg SPO2 ● Patient: Adult, child ● Range: 0 -100% ● Resolution: 1 % ● Accuracy: ±2 %(90~99%), ±3 %(70~89%),unspecified (<70%) PR: ● Range: 30bpm~250bpm ● Resolution: 1bpm ● Accuracy: ±2bpm Temperature ● Channel: 1 ● Input: Body surface thermal-sensitive resistor temperature sensor ● Measurement Unit: °C/°F selectable ● Range: 0~50℃ ● Resolution: 0.1℃ ● Accuracy: ±0.1℃ ● Environment: Temperature ● Operation: 0°C~45°C ● Transportation and storage: -20°C~60°C Humidity ● Operation: 15%~95 %( non-condensing) ● Transportation and storage: 10%~95% (non-condensing) Altitude ● Operation: 86kPa ~106kPa ● Transportation and storage: 50kPa~106kPa Power Requirements AC power adaptor ● Input: AC 100~240V, 50/60Hz, 0.7A ● Output: DC 8.4V,1A Internal battery ● Type: 1500mAh/7.2V Li-ion rechargeable battery ● Operating Time: 5 hours of stand-by time with a full battery. ● Recharge time: 8 hours |