DGC-I HANDHELD MULTI-PARAMETER MONITOR ★. Five Parameters: ECG, NIBP, SPO2 ,TEMP ,HR/PR ★. Two Waveforms: ECG waveform and SPO2 waveform (PLETH). Features: ★. Utility PC software package for long time monitoring,web transferring ★. History data uploading/review/printing/storage ★. Friendly user interfaces,touch screen,bright color LCD real time display ★. Display the measurements and waveform at the same time ★. The ECG waveform and PLETH being switched freely ★. Storage and review trend data up to 3888 groups ★. Palm, compact ,easy for carrying and operation ★. Built-in rechargeable Li-ion battery ★. Low battery power indicator ★. Automatic shut down,the shut down time adjustable from 2-15min Standard Packing List: ■ 3-lead ECG cable ( include surface TEMP probe) ■ Adult finger SPO2 sensor ■ Adult NIBP cuff ■ NIBP extension tube ■ PC software CD ■ USB cable ■ AC power adaptor ■ Wall bracket ● H.S.Code: 90181930 ● Dimension: 154×128×40mm ● Net Weight: 480g ● Gross Weight: 2.2kg ● Package Size: 300X210X90mm ● Color: Yellow and White Technical Specification: (1) General Specifications: ● Display Specification ● Measurement Display: color LCD/touch screen ● Power Supply Indicator: Dual-color LED (red/green) ● Beat indicator: Dual-color LED (red/green) (2) Power Supply AC Power Adaptor ● Input: 100~240VAC, 50/60Hz, 0.7A ● Output: DC 4.2V, 800mA Battery ● Li-ion rechargeable battery, 3.7V, 5AHr ● Operating Time: 5 hours with full battery capacity. (Condition: 25℃, NIBP working period is 10 minutes) ● Recharge Time: 10 hours. (3) Environment Temperature ● Working: 0 ~ 45 (°C) ● Transport and Storage: -25~ 85 (°C) Humidity ● Working: 30% ~85 % ● Transport and Storage: 30% ~95 % (no condensation) (4) Monitoring Parameter ECG ● Input: 3- lead ECG cable, standard AAMI cable connector ● Lead Selection: I,II,III ● Gain Selection: ×1,×2,×4,×8 ● Sweep Speed: 12.5, 25, and 50 mm/s ● Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB) ● Calibration Signal: 1mV square wave ● Protection: Against electrosurgical interference and defibrillation Heart Rate ● Measuring Range: 30~250 bpm ● Renew Time: 1 time per beat ● Accuracy: ±1 bpm ● Alarm Mode: Audible and visual alarm SPO2 ● SPO2% ● Measuring Range: 0~100% ● Resolution: 1 % ● Accuracy: ±2 %(70%~99%), unspecified (0%~69%) Pulse Rate ● Measuring and Alarm Range: 0~250bpm ● Resolution: 1bpm ● Accuracy: ±1bpm NIBP ● Method: Oscillometric ● Mode: Manual, Auto, STAT ● Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 60 (min) ● Measuring Period in STAT Mode: 5 min ● Cuff Pressure Range: 0~300 (mmHg) ● Pulse Rate Range: 30~250 (bpm) ● Measurement Rage: Adult 30~255mmHg, Pediatric 30~160mmHg ● Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg ● Pressure Resolution : 1mmHg ● The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those measured by trained medical personnel using cuff and stethoscope. The MEAN value measured using this device is equal to that measured using blood pressure measurement device. Temperature ● Input: Body surface thermal-sensitive resistor temperature sensor ● Measuring Range: 0~50℃ ● Accuracy: ±0.1℃ (5) Storage and Review ● Maximum Data Quantity: 3888 groups ● Maximum Trend Time: Continuous 129 hours  Storage Screen Monitor Screen |
 Setup Screen Special Software-Guardian 2009 for DGC-I New Style |
|