DGC2000 MULTI-PARAMETERS PATIENT MONITOR ★. Six standard parameters: ECG,RESP,NIBP,SPO2,TEMP,PR/HR Features: ★. 20 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titration table; ★. Efficient resistance to interference of defibrillator and electrosurgical cautery; ★. SPO2 can testing for 0.1% Weak; ★. RA-LL impedance Respiration; ★. Trend Coexist Display; ★. OxyCRG DyNamic View Display; ★. Bed to Bed view Display; ★. Networking capacity and nurse_calling system; ★. Options of printing, IBP, VGA and EtCO2; ★. UP to 4 hours working capacity of built_in rechargeable battery; ★. 10.4"high resolution color TFT LCD display; ★. Large volume of tabular and graphic trends information storage and easy to recall; ★. Anti-ESU, anti- defibrillator; ★. Capture dynamic waveforms. Standard Packing List: ■ 5-lead ECG cable ( including RESP) ■ Adult finger SpO2 sensor ■ Adult NIBP cuff ■ NIBP extension tube ■ TEMP sensor ■ AC power adaptor ■ ECG electrodes ■ Operation instruction Selectable Accessory: ● Child finger SPO2 sensor ● Child NIBP cuff ● Neonate NIBP cuff ● H.S. Code: 90181930 ● Dimension: 320×160×270mm ● Net Weight: <5kg ● Gross Weight: <8kg ● Package Size: 445×285×365mm ● Color: White 
Technical Specifications: ECG ● Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V) ● Lead selection: I, II, III, avR, avL, avF, V, ● Waveform: 2 ch ● Lead mode: 3 Leads ( R, L, F or RA, LA, LL) ● Lead selection: I, II, III, ● Waveform: 1 ch ● Gain: ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, auto HR and Alarm Range ● Adult: 15 ~ 300 bpm ● Neo/Ped: 15 ~ 350 bpm ● Accuracy: ± 1% or ± 1bpm,which great ● Resolution: 1 bpm ● Sensitivity: > 200 (uV P-P) ● Differential Input Impedance: > 5 MΩ CMRR ● Monitor: > 105 dB ● Operation: > 105 dB ● Diagnosis: > 85 dB ● Electrode offset potential: ±300mV ● Leakage Current: < 10 uA ● Baseline Recovery: < 3 S After Defi. ● ECG Signal Range: ±8 m V ( Vp-p ) Bandwidth ● Surgery: 1 ~ 15 Hz ● Monitor: 0.5 ~ 35 Hz ● Diagnostic: 0.05 ~ 100 Hz ● Calibration Signal: 1 (mV p-p), Accuracy:±5% ● ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV ARR Detecting ● Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC ● Alarm: Available ● Review: Available Respiration ● Method: Impedance between R-F(RA-LL) ● Differential Input Impedance: >2.5 MΩ ● Measuring Impedance Range: 0.3~5.0Ω ● Base line Impedance Range: 0 – 2.5 KΩ ● Bandwidth: 0.3 ~ 2.5 Hz ● Resp. Rate ● Measuring and Alarm Range ● Adult: 0 ~ 120 rpm ● Neo/Ped: 0 ~ 150 rpm ● Resolution: 1 rpm ● Accuracy: ±2 rpm ● Apean Alarm: 10 ~ 40 S NIBP ● Method: Oscillometric ● Mode: Manual, Auto, STAT ● Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min) ● Measuring Period in STAT Mode: 5 Min ● Pulse Rate Range: 40 ~ 240 bpm ● Alarm Type: SYS, DIA, MEAN ● Measuring and alarm range Adult Mode ● SYS: 40 ~ 270 mmHg ● DIA: 10 ~ 215 mmHg ● MEAN: 20 ~ 235 mmHg Pediatric Mode ● SYS: 40 ~ 200 mmHg ● DIA: 10 ~ 150 mmHg ● MEAN:20 ~ 165 mmHg Neonatal Mode ● SYS: 40 ~ 135 mmHg ● DIA:10 ~ 100 mmHg ● MEAN:20 ~ 110 mmHg ● Resolution Pressure:1mmHg ● Accuracy Pressure Maximum Mean error: ±5mmHg ● Maximum Standard deviation: ±8mmHg ● Overpressure Protection ● Adult Mode: 297±3 mmHg ● Pediatric Mode: 240±3 mmHg ● Neonatal Mode: 147±3 mmHg SpO2 ● Measuring Range: 0 ~ 100 % ● Alarm Range: 0 ~ 100 % ● Resolution: 1 % ● Accuracy: 70% ~ 100% ±2 % 0% ~ 69% unspecified ● Actualization interval: about 1 Sec. ● Alarm Delay: 10 Sec. Pulse Rate ● Measuring and Alarm Range: 20~300bpm ● Resolution: 1bpm ● Accuracy: ±2bpm Temperature ● Channel: 1 ● Measuring and Alarm Range: 0 ~ 50 °C ● Resolution: 0.1°C ● Accuracy: ±0.1°C ● Actualization interval: about 1 Sec. ● Average Time Constant:<10 Sec. IBP ● Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 ● Measuring and alarm range ● ART: 0 ~ 300 mmHg ● PA: -6 ~ 120 mmHg ● CVP/RAP/LAP/ICP: -10 ~ 40 mmHg ● P1/P2: -10 ~ 300 mmHg ● Press Sensor ● Sensitivity: 5 uV/V/mmHg ● Impedance: 300-3000Ω ● Resolution: 1 mmHg ● Accuracy: ±2% or ±1mmHg, which great ● Actualization interval: about 1 Sec |