DGC2000 MULTI-PARAMETERS PATIENT MONITOR

★. Six standard parameters: ECG,RESP,NIBP,SPO2,TEMP,PR/HR

Features:

★. 20 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titration table;  

★. Efficient resistance to interference of defibrillator and electrosurgical cautery;  

★. SPO2 can testing for 0.1% Weak;   

★. RA-LL impedance Respiration;  

★. Trend Coexist Display;  

★. OxyCRG DyNamic View Display;  

★. Bed to Bed view Display;  

★. Networking capacity and nurse_calling system;  

★. Options of printing, IBP, VGA and EtCO2;  

★. UP to 4 hours working capacity of built_in rechargeable battery;  

★. 10.4"high resolution color TFT LCD display;  

★. Large volume of tabular and graphic trends information storage and easy to recall;  

★. Anti-ESU, anti- defibrillator;

★. Capture dynamic waveforms.

Standard Packing List:  

 5-lead ECG cable ( including RESP)  

 Adult finger SpO2 sensor  

Adult NIBP cuff  

 NIBP extension tube  

TEMP sensor  

AC power adaptor  

 ECG electrodes  

 Operation instruction  

Selectable Accessory:  

 Child finger SPO2 sensor  

 Child NIBP cuff

 Neonate NIBP cuff

  

 H.S. Code: 90181930  

 Dimension: 320×160×270mm  

 Net Weight: <5kg  

 Gross Weight: <8kg  

 Package Size: 445×285×365mm

 Color: White

Technical Specifications:  

ECG  

 Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)  

 Lead selection: I, II, III, avR, avL, avF, V,  

Waveform: 2 ch  

 Lead mode: 3 Leads ( R, L, F or RA, LA, LL)  

 Lead selection: I, II, III,  

 Waveform: 1 ch  

 Gain: ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV,  auto  

HR and Alarm  

Range  

 Adult: 15 ~ 300 bpm  

 Neo/Ped: 15 ~ 350 bpm  

 Accuracy: ± 1% or ± 1bpm,which great  

Resolution: 1 bpm  

 Sensitivity: > 200 (uV P-P)  

 Differential Input Impedance: > 5 MΩ  

CMRR  

 Monitor: > 105 dB  

 Operation: > 105 dB  

 Diagnosis: > 85 dB  

 Electrode offset potential: ±300mV  

 Leakage Current: < 10 uA  

 Baseline Recovery: < 3 S  After Defi.  

 ECG Signal Range: ±8 m V ( Vp-p )  

Bandwidth    

 Surgery: 1 ~ 15 Hz  

 Monitor: 0.5 ~ 35 Hz  

 Diagnostic: 0.05 ~ 100 Hz  

 Calibration Signal: 1 (mV p-p),  Accuracy:±5%   

 ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV  

ARR Detecting  

 Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC,  

          TACHY, BRADY, MISSED BEATS, PNP, PNC  

 Alarm: Available  

 Review: Available  

Respiration  

 Method: Impedance between R-F(RA-LL)  

 Differential Input Impedance: >2.5 MΩ  

 Measuring Impedance Range: 0.3~5.0Ω  

 Base line Impedance Range: 0 – 2.5  KΩ  

 Bandwidth: 0.3 ~ 2.5 Hz  

 Resp. Rate  

 Measuring and Alarm Range  

 Adult: 0 ~ 120 rpm  

 Neo/Ped: 0 ~ 150 rpm  

Resolution: 1 rpm  

 Accuracy: ±2 rpm  

Apean Alarm: 10 ~ 40 S  

NIBP  

 Method: Oscillometric  

 Mode: Manual, Auto, STAT  

 Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)  

 Measuring Period in STAT Mode: 5 Min  

 Pulse Rate Range: 40 ~ 240 bpm  

 Alarm Type: SYS, DIA, MEAN  

 Measuring and alarm range  

   Adult Mode  

 SYS: 40 ~ 270 mmHg  

 DIA: 10 ~ 215 mmHg  

 MEAN: 20 ~ 235 mmHg  

  Pediatric Mode  

SYS: 40 ~ 200 mmHg  

 DIA: 10 ~ 150 mmHg  

 MEAN:20 ~ 165 mmHg  

  Neonatal Mode  

 SYS: 40 ~ 135 mmHg  

 DIA:10 ~ 100 mmHg  

 MEAN:20 ~ 110 mmHg  

 Resolution Pressure:1mmHg  

 Accuracy  Pressure  Maximum Mean error: ±5mmHg  

 Maximum Standard deviation: ±8mmHg  

Overpressure Protection  

 Adult Mode: 297±3 mmHg  

 Pediatric Mode: 240±3 mmHg  

 Neonatal Mode: 147±3 mmHg  

SpO2  

 Measuring Range: 0 ~ 100 %  

 Alarm Range: 0 ~ 100 %

 Resolution: 1 %  

 Accuracy: 70% ~ 100% ±2 %  

     0% ~ 69% unspecified  

 Actualization interval: about 1 Sec.  

 Alarm Delay: 10 Sec.  

Pulse Rate  

 Measuring and Alarm Range: 20~300bpm  

 Resolution: 1bpm  

 Accuracy: ±2bpm  

Temperature  

 Channel: 1  

 Measuring and Alarm Range: 0 ~ 50 °C  

 Resolution: 0.1°C  

 Accuracy: ±0.1°C  

Actualization interval: about 1 Sec.  

 Average Time Constant:<10 Sec.  

IBP  

 Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2  

 Measuring and alarm range  

 ART: 0 ~ 300 mmHg  

 PA: -6 ~ 120 mmHg  

 CVP/RAP/LAP/ICP: -10 ~ 40 mmHg  

 P1/P2: -10 ~ 300 mmHg  

Press Sensor  

 Sensitivity: 5 uV/V/mmHg  

 Impedance: 300-3000Ω  

 Resolution: 1 mmHg  

 Accuracy: ±2% or ±1mmHg, which great

 Actualization interval: about 1 Sec  

© 2008 - 2018 Dragon Group China -